Skip to content

Technical Sprays

Maintenance, assembly, disconnection.

All technical sprays
Search for application

Construction chemicals

Sealing, bonding, flooring.

All construction chemicals
Search for application

PERMABOND UV640

https://www.silitech.ch/web/image/product.template/1275/image_1920?unique=f685c22

1K UV-curing adhesive (methacrylic acid ester) for plastics, colorless; for plastics such as polycarbonate, including UV-stabilized polycarbonate, and for glass.
Viscosity 3,000–5,000 mPa·s; setting time acrylic 10 s at 4 mW/cm² (365–420 nm); Shore D 55–75

UV adhesive for plastics, medium viscosity — UV630 variant with higher gap-filling capacity.

Price on request

  • Manufacturer
  • Brand
  • Container
  • Color
  • Country of origin
  • Chemical group
  • Viscosity (adhesives)
  • Viscosity at 20 rpm
  • Specific Gravity
  • Curing Wavelength
  • Operating temperature (°C)
  • Storage Temperature (°C)
  • Tensile strength (ISO37)
  • Refractive index
  • Elongation at break (elasticity) (ISO37)
  • Hardness (Shore D)
  • Dielectric Strength
  • Dielectric constant 1MHz at 25°C
  • Water absorption (ISO62) 2 hrs in boiling water
  • Shear strength polycarbonate
  • Acrylic

This combination does not exist.

UV-curing metal, plastic, glass

 
General Terms and Conditions

Shipping usually within 1 to 3 business days
(Availability confirmed after order)

Express logistics. Fast and reliable within Switzerland & Europe

From Swiss stock Dispatch within 24h Batch certificate Invoice 30 days (B2B) Technical advice
Shipping & Delivery

Usually 1 to 3 business days

Availability is confirmed after order receipt.

Express logistics within Switzerland & Europe.

Terms and Conditions →

Product data

HS Code: 3506.9190000


HS Code: 3506.9190000

PERMABOND UV640
PERMABOND UV640
Permabond · Permabond Engineering Adhesives Ltd ·

Permabond UV640 is the medium viscosity variant of the plastic UV adhesive UV630 — same curing chemistry and polycarbonate affinity, but better gap-filling ability for standard geometries.

With a viscosity of 3,000–5,000 mPa·s, UV640 is significantly more viscous than UV630 (250 mPa·s) and fills standard adhesive gaps without running. Its affinity for plastics remains the same: polycarbonate bonding leads to substrate failure.

Long-wave curing (365–420 nm) is the key to processing UV-stabilized plastics — where standard UV adhesives would not cure.

APPLICATION PROFILE

UV630 with higher viscosity and better gap -filling capacity — same plastic affinity, same curing chemistry 365–420 nm. Medium viscosity consistency for standard gaps in plastic bonding.

Permabond UV640 in figures
3'000–5'000
mPa·s average
110 %
Elongation at break
Gap-filling
Standard column
365–420 nm
Long wavelength

What makes Permabond UV640 stand out

Medium viscosity
3,000–5,000 mPa s — standard gap geometry.
Long-wavelength UV curing
365–420 nm — UV-stabilized plastics.
Excellent plastic adhesion
Polycarbonate substrate failure.
110% elongation at break
Flexible and impact-resistant.
Optically invisible
Colorless adhesive seam.
Fast UV curing
1 second at 30 W/cm² light guide.

What is Permabond UV640 used for?

Polycarbonate bonding
Standard gap geometry without wicking requirement.
UV-stabilized plastics
Standard bonding with long-wave curing.
Acrylic components
Bonding with sufficient gap filling.
Plastic furniture and appliances
Standard geometry.
Industrial plastic bonding
If UV630 were too thin.

Processing

1
Clean surfaces
Prepare bonding surfaces clean, dry, and free of grease — degrease with isopropanol or acetone. For aluminum/copper, lightly sand to remove the oxide layer. For plastics, check compatibility.
2
Apply adhesive thinly
Apply Permabond UV640 thinly and evenly – directly from the bottle or using a dispensing device. Keep the adhesive protected from light. Avoid air bubbles.
3
Join and align components
Assemble quickly and precisely. For glass bonding, spread the adhesive into a thin film by applying pressure. Do not move components during UV curing.
4
Cure with UV light
Aim the UV lamp at the bond line. Curing time depends on lamp power, wavelength, and light transmission of the components — typically 1–5 seconds with a 30 W/cm² light guide system, or 5–15 seconds with a 4 mW/cm² low-power lamp.
5
Full strength after UV exposure
After complete UV curing, the components are immediately handleable. Final strength is achieved immediately after irradiation. For dual-cure products (UV + anaerobic), allow an additional 24 hours for complete anaerobic curing of shadow areas.
Data Sheets & Safety Data Sheet
Complete TDS and SDS in DE, EN, FR — view or download directly.
To the documents →

Recommended accessories


Important Notes

Not suitable for / Important notes
Store away from light. Test compatibility with thermoplastic substrates.
Storage
Store at 5 to 25 °C and protect from direct light exposure. Curing begins under UV light — keep the bottle in the dark and only open under UV-blocked light.

Which Permabond UV adhesive for which application?

Permabond UV640 in direct comparison with related products of the UV series.

Permabond UV640
Current Product
Permabond UV630 →Permabond UV645 →Permabond UV649 →
ApplicationUV adhesive for plastics (medium viscosity)Low viscosity, biocompatibleHigher gap fillingThixotropic for vertical application
Viscosity3,000–5,000 mPa·s @ 20 rpm250 mPa·s8,000–10,000 mPa·s20,000–30,000 mPa·s
Substrate Strength>9 N/mm² (substrate failure)PolycarbonatePolycarbonatePC/ABS
Elongation at break110 %110 %>70 %>70 %
Topics & Application Fields
Key terms related to this product. Also useful for our search and filters.
UV-curing metal, plastic, glass

Technical data for PERMABOND UV640

All 21 product information 4 Performance at final strength 7 Physical properties 5 Curing values ​​1 Mechanical properties 1 Shear strength ISO 4587 in N/mm² 1 Thermal properties 2
Product Information
Manufacturer Permabond Engineering Adhesives Ltd
Brand Permabond
Container 50 ml, 250 ml, 1 l, 2 l
Country of origin Italy
Performance at Full Cure
Tensile strength (ISO37) 13 N/mm²
Refractive index >1,490
Elongation at break (elasticity) (ISO37) 110%
Dielectric Strength 25-30 KV/mm
Dielectric constant 1MHz at 25°C 4
Water absorption (ISO62) 2 hrs in boiling water <5%
Shear strength polycarbonate >9 N/mm²
Physical Properties
Color colorless
Chemical group Methacrylate ester
Viscosity (adhesives) Medium viscosity 500 - 5000 mPas
Viscosity at 20 rpm 3000-5000
Specific Gravity 1.1
Curing values
Curing Wavelength 365 - 420 nm
Mechanical properties
Hardness (Shore D) 55-75
Shear strength ISO 4587 in N/mm²
Acrylic >1.5 N/mm²
Thermal Properties
Operating temperature (°C) -55 to +120
Storage Temperature (°C) 5-25

Please refer to the technical data sheet (TDS) in the "Documents" tab for binding values.

Documents and data sheets

Click on a document for the preview or the download icon for direct download.

Technical Data Sheets (TDS) 3
Permabond UV640 - Technical Data Sheet DE.pdf
308 KB
Permabond UV640 - Technical Data Sheet EN.pdf
319 KB
Permabond UV640 - Fiche Technique FR.pdf
286 KB
Safety Data Sheets (SDS) 3
Permabond UV640 - Safety Data Sheet DE.pdf
479 KB
Permabond UV640 - Safety Data Sheet EN.pdf
474 KB
Permabond UV640 - Fiche de Sécurité FR.pdf
478 KB

Frequently asked questions about Permabond UV640

Practical application and design questions — answered by SILITECH.

Permabond UV640 is a methacrylic acid ester (UV-curing, long-wavelength) adhesive with a viscosity of 3,000–5,000 mPa·s @ 20 rpm. This medium-viscosity UV adhesive for plastics offers higher gap-filling capacity than UV630. The adhesive cures upon irradiation with UV light in the spectral range of 365–420 nm—curing in seconds "on demand".

Permabond UV640 cures in the spectral range of 365–420 nm. Standard mercury vapor UV lamps, LED UV lamps with a suitable wavelength, or UV light guide systems are all suitable. For LED lamps, the maximum wavelength of the LED must be matched to the curing spectrum of the adhesive—we are happy to advise you on selecting the right lamp.

Permabond UV640 typically cures in: 5 s with a 4 mW/cm² low-power lamp; 2 s with a 100 mW/cm² LED lamp; 1 s with a 30 W/cm² UV light guide system. The exact curing time depends on the layer thickness and the light transmittance of the components.

Permabond UV640 bonds reliably to: Polycarbonate: >9 N/mm² (substrate failure); Acrylic: >1.5 N/mm². For thermoplastic substrates, we recommend testing compatibility before series production — release agents on injection-molded parts can impair adhesion.

Permabond UV640 is a UV adhesive for medium-viscosity plastics (3,000–5,000 mPa·s @ 20 rpm viscosity, 110% elongation at break). Permabond UV630 is a low-viscosity plastic adhesive (250 mPa·s, 110% elongation at break) — low viscosity, biocompatible.

When stored at 5 to 25 °C and protected from light, Permabond UV640 is stable until the printed expiration date. IMPORTANT: UV adhesives cure upon contact with light — always store the bottle in the dark and only open it briefly under UV-blocked light. Daylight-stable variants (e.g., UV675) can be used briefly under ambient light.

From the Permabond UV range, select according to substrate, viscosity, and special properties: Permabond UV640 (UV adhesive for plastics (medium viscosity)); Permabond UV630 (low-viscosity plastics); Permabond UV645 (high-viscosity plastics); Permabond UV649 (plastic gel). For shadowed areas (where UV light does not fully reach the adhesive gap), a dual-cure variant such as Permabond UV7141 (UV + anaerobic) should be used.

Your question not covered?

Our technical team provides personal advice on material selection, processing questions, and individual requirements. Fast and competent.

Product Specifications

Product Information
Container 50 ml or 250 ml or 1 l or 2 l
Manufacturer Permabond Engineering Adhesives Ltd
Brand Permabond
Country of origin Italy
Performance at Full Cure
Tensile strength (ISO37) 13 N/mm²
Refractive index >1,490
Elongation at break (elasticity) (ISO37) 110%
Dielectric Strength 25-30 KV/mm
Dielectric constant 1MHz at 25°C 4
Water absorption (ISO62) 2 hrs in boiling water <5%
Shear strength polycarbonate >9 N/mm²
Physical Properties
Color colorless
Chemical group Methacrylate ester
Viscosity (adhesives) Medium viscosity 500 - 5000 mPas
Viscosity at 20 rpm 3000-5000
Specific Gravity 1.1
Curing values
Curing Wavelength 365 - 420 nm
Mechanical properties
Hardness (Shore D) 55-75
Shear strength ISO 4587 in N/mm²
Acrylic >1.5 N/mm²
Thermal Properties
Operating temperature (°C) -55 to +120
Storage Temperature (°C) 5-25
Keywords
Keywords
UV-curing metal, plastic, glass