Skip to content

Technical Sprays

Maintenance, assembly, disconnection.

All technical sprays
Search for application

Construction chemicals

Sealing, bonding, flooring.

All construction chemicals
Search for application

PERMABOND UV612

https://www.silitech.ch/web/image/product.template/1272/image_1920?unique=8ac25b8

Permabond UV612 — UV/light-activated adhesive, Shore D 30-40.

Crystal-Clear highly flexible UV adhesive — low viscosity for high-quality glass grinding bevels.

Price on request

  • Manufacturer
  • Brand
  • Container
  • Color
  • Country of origin
  • Chemical group
  • Viscosity (adhesives)
  • Viscosity at 20 rpm
  • Specific Gravity
  • Curing Wavelength
  • Operating temperature (°C)
  • Storage Temperature (°C)
  • Tensile strength (ISO37)
  • Refractive index
  • Elongation at break (elasticity) (ISO37)
  • Hardness (Shore D)
  • Dielectric Strength
  • Dielectric constant 1MHz at 25°C
  • Water absorption (ISO62) 2 hrs in boiling water

This combination does not exist.

UV-curing

 
General Terms and Conditions

Shipping usually within 1 to 3 business days
(Availability confirmed after order)

Express logistics. Fast and reliable within Switzerland & Europe

From Swiss stock Dispatch within 24h Batch certificate Invoice 30 days (B2B) Technical advice
Shipping & Delivery

Usually 1 to 3 business days

Availability is confirmed after order receipt.

Express logistics within Switzerland & Europe.

Terms and Conditions →

Product data

HS Code: 3506.9190000


HS Code: 3506.9190000

PERMABOND UV612
PERMABOND UV612
Permabond · Permabond Engineering Adhesives Ltd ·

Permabond UV612 is a crystal-clear, low-viscosity and highly flexible UV-curing adhesive — designed for glass bonding with stress reserve and high optical clarity.

With a Shore D hardness of 30–40, UV612 is significantly softer than standard glass-to-metal UV adhesives. This flexibility buffers thermal stresses between glass and metal—important for components subjected to large temperature fluctuations or dynamic loads.

The crystal-clear optics and stability under ambient light (fluorescent lamps) make UV612 the choice for high-quality glass cut bevels and glass art that require further processing after application.

APPLICATION PROFILE

Crystal-Clear, highly flexible UV adhesive — its low hardness (30–40 Shore D) buffers thermal and mechanical stresses between glass components. Daylight-stable — processing possible after application.

Permabond UV612 in figures
Crystal
Clear as crystal
30–40
Shore D flexible
>50 %
Elongation at break
Anti-yellow
Yellowing effect.

What distinguishes Permabond UV612

Crystal Clear
Maximum transparency, resistant to yellowing.
Highly flexible
30–40 Shore D — buffers stresses.
Daylight-stable
It only hardens under UV light.
Low viscosity
450–650 mPa·s — fills narrow glass gaps.
Fast UV curing
1–2 seconds at 30 W/cm² fiber optic cable.
Resistant to yellowing
Long-term stability.

What is Permabond UV612 used for?

High-quality glass art
Crystal-clear optics with processing reserve.
Glass cut bevels
Apply adhesive before polishing.
Stress-loaded glass bonds
Flexibility buffers thermal and dynamic loads.
Glass furniture with movement requirements
If UV620 were too brittle.
Optical components
Anti-reflective adhesive, transparent combinations.

Processing

1
Clean surfaces
Prepare bonding surfaces clean, dry, and free of grease — degrease with isopropanol or acetone. For aluminum/copper, lightly sand to remove the oxide layer. For plastics, check compatibility.
2
Apply adhesive thinly
Apply Permabond UV612 thinly and evenly – directly from the bottle or using a dispensing device. Keep the adhesive protected from light. Avoid air bubbles.
3
Join and align components
Assemble quickly and precisely. For glass bonding, spread the adhesive into a thin film by applying pressure. Do not move components during UV curing.
4
Cure with UV light
Aim the UV lamp at the bond line. Curing time depends on lamp power, wavelength, and light transmission of the components — typically 1–5 seconds with a 30 W/cm² light guide system, or 5–15 seconds with a 4 mW/cm² low-power lamp.
5
Full strength after UV exposure
After complete UV curing, the components are immediately handleable. Final strength is achieved immediately after irradiation. For dual-cure products (UV + anaerobic), allow an additional 24 hours for complete anaerobic curing of shadow areas.
Data Sheets & Safety Data Sheet
Complete TDS and SDS in DE, EN, FR — view or download directly.
To the documents →

Recommended accessories


Important Notes

Not suitable for / Important notes
Store away from direct UV sources.
Storage
Store at 5 to 25 °C and protect from direct light exposure. Curing begins under UV light — keep the bottle in the dark and only open under UV-blocked light.

Which Permabond UV adhesive for which application?

Permabond UV612 in direct comparison with related products of the UV series.

Permabond UV612
Current Product
Permabond UV675 →Permabond UV620 →Permabond UV670 →
ApplicationCrystal-Clear UV adhesive, low viscosityHardener (60–70 Shore D)Standard harderA bit harder
Viscosity450–650 mPa·s @ 20 rpm500–800 mPa·s2,200–2,900 mPa·s2'000–3'000 mPa·s
Substrate Strength8–12 N/mm²8–12 N/mm²9–10 N/mm²6–10 N/mm²
Elongation at break>50 %>50 %>80 %>80 %
Topics & Application Fields
Key terms related to this product. Also useful for our search and filters.
UV-curing product range review 2026

Technical data for PERMABOND UV612

All 19 Product information 4 Performance at final strength 6 Physical properties 5 Curing values 1 Mechanical properties 1 Thermal properties 2
Product Information
Manufacturer Permabond Engineering Adhesives Ltd
Brand Permabond
Container 50 ml, 200 ml
Country of origin Italy
Performance at Full Cure
Tensile strength (ISO37) >5 N/mm²
Refractive index >1,490
Elongation at break (elasticity) (ISO37) >50%
Dielectric Strength 12 KV/mm
Dielectric constant 1MHz at 25°C 4
Water absorption (ISO62) 2 hrs in boiling water >2%
Physical Properties
Color colorless
Chemical group Methacrylate ester
Viscosity (adhesives) Low viscosity <500 MPas
Viscosity at 20 rpm 450-650
Specific Gravity 0.95
Curing values
Curing Wavelength 365-400 nm
Mechanical properties
Hardness (Shore D) 30-40
Thermal Properties
Operating temperature (°C) -55 to +120
Storage Temperature (°C) 5-25

Please refer to the technical data sheet (TDS) in the "Documents" tab for binding values.

Documents and data sheets

Click on a document for the preview or the download icon for direct download.

Safety Data Sheets (SDS) 3
Permabond UV612 - Safety Data Sheet DE.pdf
327 KB
Permabond UV612 - Safety Data Sheet EN.pdf
323 KB
Permabond UV612 - Fiche de Sécurité FR.pdf
325 KB

Frequently asked questions about Permabond UV612

Practical application and design questions — answered by SILITECH.

Permabond UV612 is a methacrylate ester (UV-curing) adhesive with a viscosity of 450–650 mPa·s @ 20 rpm. This low-viscosity, crystal-clear UV adhesive is flexible, non-yellowing, and suitable for ground glass. The adhesive cures upon exposure to UV light in the 365–400 nm spectral range, providing instant curing on demand.

Permabond UV612 cures in the spectral range of 365–400 nm. Standard mercury vapor UV lamps, LED UV lamps with a suitable wavelength, or UV light guide systems are all suitable. For LED lamps, the maximum wavelength of the LED must be matched to the curing spectrum of the adhesive—we are happy to advise you on selecting the right lamp.

Permabond UV612 typically cures in: 10–15 s with a 4 mW/cm² low-power lamp; 2–3 s with a 100 mW/cm² LED lamp; 1–2 s with a 30 W/cm² UV light guide system. The exact curing time depends on the layer thickness and the light transmittance of the components.

Permabond UV612 bonds reliably to glass/steel: 8–12 N/mm². For thermoplastic substrates, we recommend testing compatibility before series production — release agents on injection-molded parts can impair adhesion.

Permabond UV612 is a low-viscosity, crystal-clear UV adhesive (450–650 mPa·s @ 20 rpm viscosity, >50% elongation at break). Permabond UV675 is a crystal-clear hardener (500–800 mPa·s, >50% elongation at break) — hardener (60–70 Shore D).

When stored at 5 to 25 °C and protected from light, Permabond UV612 is stable until the printed expiration date. IMPORTANT: UV adhesives cure upon contact with light — always store the bottle in the dark and only open it briefly under UV-blocked light. Daylight-stable variants (e.g., UV675) can be used briefly under ambient light.

From the Permabond UV range, select according to substrate, viscosity, and special properties: Permabond UV612 (Crystal-Clear UV adhesive, low viscosity); Permabond UV675 (Crystal-Clear, harder); Permabond UV620 (Optically clear, standard); Permabond UV670 (Flexible, impact-resistant). For shadowed areas (where UV light does not fully reach the adhesive gap), a dual-cure variant such as Permabond UV7141 (UV + anaerobic) should be used.

Your question not covered?

Our technical team provides personal advice on material selection, processing questions, and individual requirements. Fast and competent.

Product Specifications

Product Information
Container 50 ml or 200 ml
Manufacturer Permabond Engineering Adhesives Ltd
Brand Permabond
Country of origin Italy
Performance at Full Cure
Tensile strength (ISO37) >5 N/mm²
Refractive index >1,490
Elongation at break (elasticity) (ISO37) >50%
Dielectric Strength 12 KV/mm
Dielectric constant 1MHz at 25°C 4
Water absorption (ISO62) 2 hrs in boiling water >2%
Physical Properties
Color colorless
Chemical group Methacrylate ester
Viscosity (adhesives) Low viscosity <500 MPas
Viscosity at 20 rpm 450-650
Specific Gravity 0.95
Curing values
Curing Wavelength 365-400 nm
Mechanical properties
Hardness (Shore D) 30-40
Thermal Properties
Operating temperature (°C) -55 to +120
Storage Temperature (°C) 5-25
Keywords
Keywords
UV-curing