Technical Data
Typical values, not a specification. The technical data sheet (TDS) is binding.
Mechanical properties
- Shore hardness A
- 20 Shore A
- Tensile Strength
- 5 MPa
- Elongation at break
- 650 %
- Tear resistance
- 15 kN/m
- Linear shrinkage
- < 0.1 %
Processing
- Viscosity of Mixture
- 4,000 mPa·s
- Viscosity Component A
- 4,000 mPa·s
- Viscosity Component B
- 4,000 mPa·s
- Pot life at 23 °C
- 50 min
Physical and thermal
- Density (23 °C)
- 1.07 g/cm³
- Temperature resistance (duration)
- -50 to 150 °C
- Peak temperature (briefly)
- 150 °C
Storage
- Shelf life in original packaging
- 12 months
- Storage Temperature
- -5 to 30 °C
Product Information
- Brand
- Silbione
- Manufacturer
- Elkem Silicones
- Mixing Ratio
- 1 : 1
- Curing type
- Addition (Platinum)
- Container
- 200ml + 200ml, 1kg + 1kg, 5kg + 5kg
- Number of components
- 2K (two-component)
- Consistency
- Flowable
- Mixing Ratio
- 1:1
Further Properties
- UV resistance
- No
Physical Properties
- Cured Color
- Transparent
- Self-leveling
- Yes
- Density (g/cm³)
- 1.07
- Uncrosslinked viscosity (mPa·s)
- 4000
Electrical Properties
- Electrical Insulation
- No
Product Approvals
- Food contact
- Yes
- Medical grade
- Yes
Mechanical properties
- Tensile strength (MPa)
- 5
- Elongation at break (%)
- 650
- Tensile strength (N/mm)
- 15
Product Description
Two-component, platinum-curing silicone elastomer that cures at room temperature via a polyaddition reaction and whose curing can be accelerated by heat. Very high elongation, low viscosity, sterilizable according to TDS; hardness according to TDS approx. Shore A 20.
SILBIONE RTV 4420 A&B is supplied as two low-viscosity, liquid components and mixed in a 1:1 weight ratio. After curing, it forms an elastic, resistant material; polymerization occurs without heat generation and can be accelerated by heat, e.g., 60 minutes at 80°C according to the Elkem data sheet. Compared to SILBIONE RTV 4411, the viscosity is lower (approx. 4000 mPa·s) and the hardness higher (approx. Shore A 20). According to the Elkem data sheet, it is positioned for heel cushions, toe separators, and liners for limb prostheses.
According to the Elkem data sheet, extensive toxicological tests on SILBIONE products have demonstrated sufficient biocompatibility and suitability for the recommended applications; SILBIONE RTV 4420 A and B meet regulatory requirements in several countries and comply with a range of medical and pharmaceutical regulations, according to the Elkem data sheet. We can assist you with selection and approval for medical or skin contact applications.
What makes the SILBIONE RTV 4420 stand out
What is SILBIONE RTV 4420 used for?
Processing
Important Notes
- Crosslinking can be inhibited by contact with certain substances: sulfur-crosslinked natural rubber, RTV-2 silicones catalyzed with metal salts (e.g., tin compounds), PVC stabilized with tin salts, and amine-catalyzed epoxy resins. If in doubt, test the substrate on a small area beforehand.
- The currently valid Elkem data sheet (TDS and SDS) is authoritative, which we will be happy to send you.
Frequently asked questions about SILBIONE RTV 4420
Practical application and design questions, answered by SILITECH.
According to the Elkem data sheet, A:B 1:1 by weight, pot life approx. 50 min at 23°C.
Polymerization occurs at 23°C, which can be accelerated by heat, according to TDS e.g. 60 minutes at 80°C.
According to TDS, 4420 has a lower viscosity (approx. 4000 mPa·s) and a higher hardness (approx. Shore A 20) than 4411; the elongation at break is lower at approx. 650%.
According to TDS, in original packaging, storage time is up to 12 months from the date of manufacture (components A and B) at -5°C to 30°C.