If an addition-curing silicone remains soft or sticky, several causes are possible. Besides inhibition of the platinum catalyst, incorrect dosage, incomplete mixing, or unsuitable curing conditions should also be checked.
1. Understand the product and processing
Check the exact names of the base and catalyst, their expiration dates, and the prescribed component assignments. Verify the mixing ratio and its reference unit: a weight-based ratio does not automatically equate to a volume-based ratio. Record the actual material temperature, the start of mixing, and the curing time to date.
The mixture must be homogeneous on the container walls and bottom. Soft streaks can indicate insufficient mixing, but do not prove the cause.
2. Prepare a control sample without the suspected contact material
Using clean, suitable mixing equipment, prepare a small sample according to the processing instructions. Allow it to cure under the recommended conditions. Simultaneously, another sample can be tested on the intended substrate. This will help determine whether the defect occurs even without the substrate or is related to a contact material.
3. Consider possible inhibitors
WACKER cites certain sulfur-, amine-, and tin-containing substances as potential sources of interference with addition-curing silicones. Release agents, cleaning residues, or additives can also play a role, depending on their composition. Therefore, the specific material and its condition during processing are crucial.
Gloves must meet the protection requirements specified in the safety data sheet and be suitable for the process. A general recommendation based solely on the glove material designation does not replace this testing.
4. Confirm the remedy with a small sample
After any change to the cleaning process, auxiliary material, or surface, the comparison is repeated. A successful test is initially valid for the tested combination and the documented conditions. Before larger-scale production, the application must be confirmed on the intended geometry.
Handle uncured material according to the instructions in the safety data sheet. Pouring more silicone over it will not reliably eliminate an unknown cause. If the control test also fails, product, batch, and processing information will help when contacting the supplier.
Further source
The current product documentation is decisive for processing.