Skip to content

PERMABOND UV640

https://www.silitech.ch/web/image/product.template/1275/image_1920?unique=292488b

Permabond UV640 — UV/light-activated adhesive, Shore D 55-75.

UV adhesive for plastics, medium viscosity — UV630 variant with higher gap-filling capacity.

CHF 0.00 CHF 0.00 CHF 0.00 Excluding taxes

CHF 0.00 excluding taxes

Price on request

  • Manufacturer
  • brand
  • Container
  • Color
  • Country of origin
  • Chemical group
  • Viscosity (adhesives)
  • Viscosity 20rpm
  • Specific gravity
  • Curing wavelength
  • Operating temperature (°C)
  • Storage temperature (°C)
  • Tensile strength (ISO37)
  • Refractive index
  • Elongation at break (elasticity) (ISO37)
  • Hardness (Shore D)
  • Dielectric strength
  • Dielectric constant 1MHz at 25°C
  • Water absorption (ISO62) 2 hours in boiling water
  • Shear strength polycarbonate
  • Acrylic

This combination does not exist.

Add to cart Request sample
UV-curing metal, plastic, glass

 
General Terms and Conditions.

Shipping usually within 1 to 3 business days
(availability will be confirmed after ordering)

. Express logistics. Fast and reliable within Switzerland & Europe.

Shipping from Swiss warehouse within 24 hours. Batch certificate. Invoice within 30 days (B2B). Technical support.
Shipping & Delivery

Usually 1 to 3 working days

Availability will be confirmed after order receipt.

Express logistics within Switzerland & Europe.

General Terms and Conditions →

Product data

Internal reference: 49-640.FL

HS code: 3506.9190000


Internal reference: 49-640.FL
HS code: 3506.9190000

PERMABOND UV640
PERMABOND UV640
Permabond · Permabond Engineering Adhesives Ltd · SKU 49-640.FL

Permabond UV640 is the medium viscosity variant of the plastic UV adhesive UV630 — same curing chemistry and polycarbonate affinity, but better gap-filling ability for standard geometries.

With a viscosity of 3,000–5,000 mPa·s, UV640 is significantly more viscous than UV630 (250 mPa·s) and fills standard adhesive gaps without running. Its affinity for plastics remains the same: polycarbonate bonding leads to substrate failure.

Long-wave curing (365–420 nm) is the key to processing UV-stabilized plastics — where standard UV adhesives would not cure.

APPLICATION PROFILE

UV630 with higher viscosity and better gap -filling capacity — same plastic affinity, same curing chemistry 365–420 nm. Medium viscosity consistency for standard gaps in plastic bonding.

Permabond UV640 in figures
3'000–5'000
mPa·s average
110 %
Elongation at break
Gap-filling
Standard column
365–420 nm
Long wavelength

What makes Permabond UV640 stand out

Medium viscosity
3,000–5,000 mPa s — standard gap geometry.
Long-wave UV curing
365–420 nm — UV-stabilized plastics.
Excellent plastic adhesion
Polycarbonate substrate failure.
110% elongation at break
Flexible and impact-resistant.
Optically invisible
Colorless adhesive seam.
Fast UV curing
1 second at 30 W/cm² optical fiber.

What is Permabond UV640 used for?

Polycarbonate bonding
Standard gap geometry without wicking requirement.
UV-stabilized plastics
Standard bonding with long-wave curing.
Acrylic components
Bonding with sufficient gap filling.
Plastic furniture and appliances
Standard geometry.
Industrial plastic bonding
If UV630 were too thin.

processing

1
Clean surfaces
Prepare bonding surfaces to be clean, dry, and free of grease — degrease with isopropanol or acetone. For aluminum/copper, lightly sand to remove the oxide layer. Test compatibility on plastics.
2
Apply adhesive thinly
Apply Permabond UV640 thinly and evenly – directly from the bottle or using a dispensing device. Keep the adhesive protected from light. Avoid air bubbles.
3
Adding and aligning components
Quickly and precisely assemble. When bonding glass, spread the adhesive into a thin film by applying pressure. Do not move components during UV curing.
4
Cure with UV light
Point the UV lamp at the adhesive gap. Curing time depends on the lamp power, wavelength, and light transmittance of the components — typically 1–5 seconds for a 30 W/cm² fiber optic system or 5–15 seconds for a 4 mW/cm² low-power lamp.
5
Full strength after UV irradiation
After complete UV curing, the components are immediately ready for handling. Final strength is achieved immediately after irradiation. For dual-cure products (UV + anaerobic), an additional 24 hours are required for complete anaerobic curing of the shaded areas.
Data sheets & safety data sheet
Full TDS and SDS in DE, EN, FR — view or download directly.
To the documents →

Recommended accessories


Important instructions

Not suitable for / Important notes
Store away from light. Test compatibility with thermoplastic substrates.
storage
Store at 5 to 25 °C and protect from direct sunlight. Curing begins under UV light — keep the bottle in the dark and open only under UV-blocked light.

Which Permabond UV adhesive is suitable for which application?

Permabond UV640 in direct comparison with related products of the UV series.

Permabond UV640
Current product
Permabond UV630 →Permabond UV645 →Permabond UV649 →
ApplicationUV adhesive for plastics (medium viscosity)Low viscosity, biocompatibleHigher gap fillingThixotropic for vertical application
viscosity3,000–5,000 mPa·s @ 20 rpm250 mPa·s8,000–10,000 mPa·s20,000–30,000 mPa·s
Substrate strength>9 N/mm² (substrate failure)PolycarbonatPolycarbonatPC/ABS
Elongation at break110 %110 %>70 %>70 %
Topics & Application Areas
Key terms related to this product. Also useful for our search and filters.
UV-curing metal, plastic, glass

Technical data for PERMABOND UV640

All 21 product information 4 Performance at final strength 7 Physical properties 5 Curing values ​​1 Mechanical properties 1 Shear strength ISO 4587 in N/mm² 1 Thermal properties 2
Product information
Manufacturer Permabond Engineering Adhesives Ltd
brand Permabond
Container 50 ml, 250 ml, 1 l, 2 l
Country of origin Italy
Performance at final strength
Tensile strength (ISO37) 13 N/mm²
Refractive index >1,490
Elongation at break (elasticity) (ISO37) 110%
Dielectric strength 25-30 KV/mm
Dielectric constant 1MHz at 25°C 4
Water absorption (ISO62) 2 hours in boiling water <5%
Shear strength polycarbonate >9 N/mm²
Physical properties
Color colorless
Chemical group Methacrylic acid esters
Viscosity (adhesives) Medium viscosity 500 - 5000 mPas
Viscosity 20rpm 3000-5000
Specific gravity 1.1
Curing values
Curing wavelength 365 - 420 nm
Mechanical properties
Hardness (Shore D) 55-75
Shear strength ISO 4587 in N/mm²
Acrylic >1.5 N/mm²
Thermal properties
Operating temperature (°C) -55 to +120
Storage temperature (°C) 5-25

For binding values, please refer to the technical data sheet (TDS) in the "Documents" tab.

Documents and datasheets

Click on a document for a preview or the download icon for a direct download.

Technical Data Sheets (TDS) 3
Permabond UV640 - Technical Data Sheet DE.pdf
308 KB
Permabond UV640 - Technical Data Sheet EN.pdf
319 KB
Permabond UV640 - Fiche Technique FR.pdf
286 KB
Safety Data Sheets (SDS) 3
Permabond UV640 - Safety Data Sheet DE.pdf
479 KB
Permabond UV640 - Safety Data Sheet EN.pdf
474 KB
Permabond UV640 - Fiche de Sécurité FR.pdf
478 KB

Frequently asked questions about Permabond UV640

Practical application and design questions — answered by SILITECH.

Permabond UV640 is a methacrylic acid ester (UV-curing, long-wavelength) adhesive with a viscosity of 3,000–5,000 mPa·s @ 20 rpm. This medium-viscosity UV adhesive for plastics offers higher gap-filling capacity than UV630. The adhesive cures upon irradiation with UV light in the spectral range of 365–420 nm—curing in seconds "on demand".

Permabond UV640 cures in the spectral range of 365–420 nm. Standard mercury vapor UV lamps, LED UV lamps with a suitable wavelength, or UV light guide systems are all suitable. For LED lamps, the maximum wavelength of the LED must be matched to the curing spectrum of the adhesive—we are happy to advise you on selecting the right lamp.

Permabond UV640 typically cures in: 5 s with a 4 mW/cm² low-power lamp; 2 s with a 100 mW/cm² LED lamp; 1 s with a 30 W/cm² UV light guide system. The exact curing time depends on the layer thickness and the light transmittance of the components.

Permabond UV640 bonds reliably to: Polycarbonate: >9 N/mm² (substrate failure); Acrylic: >1.5 N/mm². For thermoplastic substrates, we recommend testing compatibility before series production — release agents on injection-molded parts can impair adhesion.

Permabond UV640 is a UV adhesive for medium-viscosity plastics (3,000–5,000 mPa·s @ 20 rpm viscosity, 110% elongation at break). Permabond UV630 is a low-viscosity plastic adhesive (250 mPa·s, 110% elongation at break) — low viscosity, biocompatible.

When stored at 5 to 25 °C and protected from light, Permabond UV640 is stable until the printed expiration date. IMPORTANT: UV adhesives cure upon contact with light — always store the bottle in the dark and only open it briefly under UV-blocked light. Daylight-stable variants (e.g., UV675) can be used briefly under ambient light.

From the Permabond UV range, select according to substrate, viscosity, and special properties: Permabond UV640 (UV adhesive for plastics (medium viscosity)); Permabond UV630 (low-viscosity plastics); Permabond UV645 (high-viscosity plastics); Permabond UV649 (plastic gel). For shadowed areas (where UV light does not fully reach the adhesive gap), a dual-cure variant such as Permabond UV7141 (UV + anaerobic) should be used.

Your question isn't listed here

Our technical team will advise you personally on material selection, processing questions, and individual requirements. Quickly and competently.

Product specifications

Product information
Container 50 ml or 250 ml or 1 l or 2 l
Manufacturer Permabond Engineering Adhesives Ltd
brand Permabond
Country of origin Italy
Performance at final strength
Tensile strength (ISO37) 13 N/mm²
Refractive index >1,490
Elongation at break (elasticity) (ISO37) 110%
Dielectric strength 25-30 KV/mm
Dielectric constant 1MHz at 25°C 4
Water absorption (ISO62) 2 hours in boiling water <5%
Shear strength polycarbonate >9 N/mm²
Physical properties
Color colorless
Chemical group Methacrylic acid esters
Viscosity (adhesives) Medium viscosity 500 - 5000 mPas
Viscosity 20rpm 3000-5000
Specific gravity 1.1
Curing values
Curing wavelength 365 - 420 nm
Mechanical properties
Hardness (Shore D) 55-75
Shear strength ISO 4587 in N/mm²
Acrylic >1.5 N/mm²
Thermal properties
Operating temperature (°C) -55 to +120
Storage temperature (°C) 5-25
Keywords
Keywords
UV-curing metal, plastic, glass