Skip to content

Technical Sprays

Maintenance, assembly, disconnection.

All technical sprays
Search for application

Construction chemicals

Sealing, bonding, flooring.

All construction chemicals
Search for application

PermabondUV-curing adhesives

PERMABOND 4UV80HV

High-viscosity, UV/light-curing methacrylate adhesive of medical device grade — cure-on-demand with low-power lamps, ISO 10993-5 biocompatible

Chemical group
Methacrylate ester
Color
colorless
Specific Gravity
1.1
Tensile strength (ISO37)
12 N/mm²

CHF 0.00 / pc.
  • Brand
  • Manufacturer
  • Country of origin
  • Container
  • Chemical group
  • Color
  • Specific Gravity
  • Flash point
  • polycarbonate
  • Tensile strength (ISO37)
  • Dielectric strength
  • Elongation at break
  • Hardness (Shore D)
  • Dielectric Strength
  • Dielectric Constant
  • Storage Temperature (°C)
Your selection PERMABOND 4UV80HV
General terms and conditions of business

HS Code: 3506919000

PERMABOND 4UV80HV sample offer

Technical Data

Typical values, not a specification. The technical data sheet (TDS) is binding.

Product Information

Brand
Permabond
Manufacturer
Permabond Engineering Adhesives Ltd
Country of origin
Italy
Container
50 ml, 1 l
Flash point
100°C

Performance at Full Cure

Tensile strength (ISO37)
12 N/mm²
Dielectric strength
4-9.5 years
Elongation at break
20%
Dielectric Strength
12 KV/mm

Physical Properties

Chemical group
Methacrylate ester
Color
colorless
Specific Gravity
1.1

Electrical Properties

Dielectric Constant
4

Mechanical properties

Hardness (Shore D)
60

Shear strength ISO 4587 in N/mm²

polycarbonate
>9 N/mm²

Thermal Properties

Storage Temperature (°C)
5-25
Keywords
  • UV-curing
  • Medical
  • ISO 10993-5 Cytotoxicity
  • Medical adhesive
  • Bonding medical devices

Product Description

Permabond 4UV80HV is a high-viscosity, UV/light-curing methacrylate adhesive of medical device quality — cure-on-demand with low-power lamps, ISO 10993-5 biocompatible.

Permabond UV/light-curing methacrylate adhesives — cure-on-demand, biocompatible, ideal for transparent substrates and automated bonding in medical device manufacturing. 4UV80HV is tailored to specific applications — the most important properties and areas of application are listed below.

Cure on demand + Medical Grade

Permabond 4UV80HV is a UV-curing methacrylate ester for medical devices — cure-on-demand allows free positioning until exposure. Excellent adhesion to medical-grade plastics and metals, cytotoxicity tested according to ISO 10993-5.

4UV80HV in figures
UV Cure
on demand
ISO 10993
biocompatible
High viscosity
opaque
100% Solids
solvent-free

What makes the 4UV80HV stand out

Cure-on-demand
Free positioning until UV exposure — no pot life stress.
ISO 10993-5 biocompatible
Cytotoxicity tested for medical applications.
High viscosity
Opaque consistency, vertical application possible.
Fast networking with low-power lamps
Efficient UV curing.
Excellent adhesion to medical plastics
Polycarbonate, acrylic, nylon.

What is the 4UV80HV used for?

Medical device assembly
UV bonding of medical device components.
Transparent substrates
Glass, polycarbonate, acrylic.
Machine-automated bonding
Robot-controlled UV curing.
Sensors and measuring instruments
Sensitive components with medical-grade compliance.
High-precision bonding
Cure-on-demand for maximum positional accuracy.
Data Sheets & Safety Data Sheet
TDS and SDS in multiple languages — view or download directly.
To the documents →

Processing

1
Clean substrate
Degrease bonding surfaces — especially transparent substrates (glass, polycarbonate) very carefully.
2
Apply UV adhesive
Cure-on-demand: Apply adhesive, join components — no rush, long open time.
3
Positioning components
Correct alignment — the position can be adjusted as desired before UV exposure.
4
UV exposure
Expose with a low-power UV lamp — curing time depends on lamp power and layer thickness. Wavelength according to TDS.
5
Curing
Instant curing under UV light. ISO 10993-5 compliant after full cross-linking.

Recommended accessories


4UV80HV in comparison

Direct comparison with related Permabond products from our range.

4UV80HV
Current Product
4C10 →4C30 →4C40 →
Chemical BaseMethacrylate esterCyanoacrylate (ethyl ester)Cyanoacrylate (ethyl ester)Cyanoacrylate (ethyl ester)
Viscosityhigh viscosity, opaquelow viscosityMedium Viscosityhigh viscosity
GradeMedical Device (ISO 10993-5)Medical DeviceMedical DeviceMedical Device
Coloropaquecolorlesscolorlesscolorless
Set TimeUV Cure (sec.)<10 s (typical)~30 s~60 s
Full CureUV-cured24 h24 h24 h
Main applicationUV Medical DeviceHard-to-bond rubbersAuto-dispenser, middle columnLarge gap + POM

Frequently asked questions about 4UV80HV

Practical application and design questions — answered by SILITECH.

Permabond 4UV80HV: High-viscosity, UV/light-curing methacrylate adhesive of medical device grade — cure-on-demand with low-power lamps, ISO 10993-5 biocompatible. Main applications: Medical device assembly, transparent substrates, automated bonding.

UV-curing adhesives only crosslink under UV exposure—without UV, they remain liquid indefinitely. The advantage: components can be freely positioned and adjusted before being selectively exposed to the UV lamp. As soon as UV light hits them, the adhesive crosslinks within seconds. Ideal for high-precision bonding with long positioning times and automated machine applications.

Store in the unopened original container in a dry, cool place — Permabond adhesives typically between +5 and +25 °C, exact values see TDS. Consult the Safety Data Sheet (SDS) before use. Observe the expiry date on the packaging. Store cyanoacrylates cool (ideally refrigerated) for maximum shelf life.

In the comparison table above, you will find related Permabond products with different properties — viscosity, mixing ratio, special certification. If you are unsure about the optimal choice, we will be happy to advise you — contact SILITECH with your specific application (substrate pairing, load, curing condition).