Skip to content

PERMABOND A136

https://www.silitech.ch/web/image/product.template/571/image_1920?unique=8ac25b8

Permabond A136 — anaerobic adhesive.

Anaerobic surface and flange gasket — metal/metal contact without shrinkage, WRAS approved.

Price on request

  • Manufacturer
  • Brand
  • Container
  • Color
  • Country of origin
  • Chemical group
  • Viscosity (adhesives)
  • Viscosity 2rpm
  • Viscosity at 20 rpm
  • Fluorescence
  • Maximum gap fill (mm)
  • Handling strength (M10 steel)@23°C
  • Functional strength (M10 steel)@23°C
  • Ultimate strength (M10 steel)@23°C
  • Shear strength (steel ISO10123)
  • Coefficient of thermal expansion
  • Dielectric Strength
  • Thermal conductivity
  • Storage Temperature (°C)
  • Operating temperature (°C)
  • Torque strength (M10 steel ISO10964) Breakloose
  • Torque strength (M10 steel ISO10964) Prevailing

This combination does not exist.

Anaerobic WRAS shaft hub PERMABOND

 
General Terms and Conditions

Shipping usually within 1 to 3 business days
(Availability confirmed after order)

Express logistics. Fast and reliable within Switzerland & Europe

From Swiss stock Dispatch within 24h Batch certificate Invoice 30 days (B2B) Technical advice
Shipping & Delivery

Usually 1 to 3 business days

Availability is confirmed after order receipt.

Express logistics within Switzerland & Europe.

Terms and Conditions →

Product data

HS Code: 3506.9190000


HS Code: 3506.9190000

PERMABOND A136
PERMABOND A136
Permabond · Permabond Engineering Adhesives Ltd ·

Permabond A136 is an anaerobic surface gasket — specifically for flange, housing and flat gaskets between metal components. It ensures metal-to-metal contact with uniform stress distribution and without volume loss.

Unlike conventional threadlockers or shaft-hub adhesives, A136 is optimized for flat surfaces — flanges, housing covers, pump bodies. Its paste consistency means it does not drip, creep, or shrink upon curing.

The bond creates direct metal-to-metal contact with a minimal adhesive gap—important for torque transmission and heat conduction. Gap filling up to 0.5 mm covers larger tolerances. WRAS approval also permits contact with drinking water.

SPECIAL FEATURE

Anaerobic surface and flange gasket — the Permabond specialist for flat sealing surfaces between metal components. No creep, no shrinkage, ensures metal-to-metal contact with minimal gaps. WRAS-approved for drinking water applications.

Permabond A136 in figures
flange
Specialty Product
0.5 mm
Gap filling
Metal/Metal
Contact
WRAS
Drinking water

What distinguishes Permabond A136

Flange and flat gasket
Specifically designed for flat sealing surfaces between metal components.
No creeping, no shrinking
Dimensionally stable — the adhesive bond does not change after curing.
Metal/metal contact with minimal gap
Direct mechanical contact, uniform voltage distribution.
0.5 mm gap filling
For coarser flange or housing tolerances.
No residue formation
It does not clog narrow channels in pumps or hydraulic systems.
WRAS approved for potable water
Direct contact with drinking water permitted.

What is Permabond A136 used for?

Flange connections
Pumps, gearboxes, motor housings — flat metal sealing surfaces.
Housing cover
Hydraulic, pneumatic and pump housings.
Drinking water pumps
WRAS-approved — Pump flanges for drinking water applications.
Industrial flat gaskets
If classic flat gaskets were unsuitable due to wear or corrosion.
Replacement of stamped seals
Applied gasket instead of paper, cork or rubber flat gasket.

Processing

1
Clean surfaces
Bonding surfaces must be clean, dry, and free of grease. Degrease with Permabond Cleaner A or a solvent (acetone, isopropanol). Rough surfaces (~25 µm) result in higher bond strength than polished ones.
2
Apply adhesive
Apply Permabond A136 directly from the bottle — for through holes, apply a stripe along the thread length; for blind holes, apply a few drops to the bottom. Do not touch the nozzle to metal surfaces (this will cause premature hardening in the bottle).
3
Joining components
Insert the screws and tighten to the desired torque. For shaft-hub fits, assemble the components before the adhesive begins to cure.
4
Allow to cure
Anaerobic curing begins in the absence of air and upon contact with metal. Handling strength is typically achieved after 15 minutes, functional strength after 1 hour, and full strength after 24 hours at 23 °C.
5
Accelerate curing (optional)
On inactive surfaces (stainless steel, zinc, aluminum) or at low temperatures, Permabond A905 activator can be used — apply to one bonding surface, allow to flash off, then apply adhesive to the other side.
Data Sheets & Safety Data Sheet
Complete TDS and SDS in DE, EN, FR — view or download directly.
To the documents →

Recommended accessories


Important Notes

Not suitable for / Important notes
Curing requires metal-to-metal contact (anaerobic). For inactive surfaces, use A905 activator. Not for contact with oxygen or vapor. Some thermoplastics may be affected.
Storage
Store at 5 to 25 °C. Anaerobic adhesives lose their reactivity upon contact with metal — do not touch the tip of the bottle to metal surfaces, and do not pour adhesive back into the bottle.

Which Permabond anaerobic adhesive for which application?

Permabond A136 in direct comparison with related products of the A series.

Permabond A136
Current Product
Permabond MH196 →Permabond A129 →Permabond A1058 →
Application / StrengthSurface and flange gasketAnaerobic surface seal redThreaded gasket instead of flat gasketHigh-viscosity pipe paste
ViscosityPaste consistencyPaste 500,000 mPa·sGel300,000 mPa·s
Max. gap fill.0.5 mm0.5 mm0.5 mm0.5 mm
Breakaway Torque10 N·m20 N·m12 N·m8 N·m
Prevailing torque8 N·m23 N·m7 N·m6 N·m
Topics & Application Fields
Key terms related to this product. Also useful for our search and filters.
Anaerobic WRAS shaft hub PERMABOND

Technical data for PERMABOND A136

All 22 product information 4 Performance at final strength 5 Physical properties 6 Curing values ​​4 Thermal properties 3
Product Information
Manufacturer Permabond Engineering Adhesives Ltd
Brand Permabond
Container 50 ml, 200 ml
Country of origin Italy
Performance at Full Cure
Shear strength (steel ISO10123) 12 MPa
Dielectric Strength 11 kV/mm
Thermal conductivity 0.19 W/(m.K)
Torque strength (M10 steel ISO10964) Breakloose 10 Nm
Torque strength (M10 steel ISO10964) Prevailing 8 Nm
Physical Properties
Color red
Chemical group Acrylic one-component
Viscosity (adhesives) High viscosity >5000 mPas
Viscosity 2rpm 75000
Viscosity at 20 rpm 18000
Fluorescence Yes
Curing values
Maximum gap fill (mm) 0.5
Handling strength (M10 steel)@23°C <30 minutes
Functional strength (M10 steel)@23°C 2 hours
Ultimate strength (M10 steel)@23°C 24 hours
Thermal Properties
Coefficient of thermal expansion 90 x 10-6 mm/mm/°C
Storage Temperature (°C) 5-25
Operating temperature (°C) -55 to 200

Please refer to the technical data sheet (TDS) in the "Documents" tab for binding values.

Documents and data sheets

Click on a document for the preview or the download icon for direct download.

Technical Data Sheets (TDS) 3
Permabond A136 - Technical Data Sheet DE.pdf
329 KB
Permabond A136 - Technical Data Sheet EN.pdf
334 KB
Permabond A136 - Fiche Technique FR.pdf
312 KB
Safety Data Sheets (SDS) 3
Permabond A136 - Safety Data Sheet DE.pdf
368 KB
Permabond A136 - Safety Data Sheet EN.pdf
364 KB
Permabond A136 - Fiche de Sécurité FR.pdf
367 KB

Frequently asked questions about Permabond A136

Practical application and design questions — answered by SILITECH.

Permabond A136 is a single-component, anaerobic acrylic sealant with a paste-like consistency and viscosity, capable of filling gaps up to 0.5 mm. It provides anaerobic surface and flange sealing – metal-to-metal contact, no shrinkage, and is WRAS approved. Anaerobic adhesives cure in the absence of air and in contact with metal – ideal for tight-tolerance metallic joints.

Anaerobic adhesives like Permabond A136 remain liquid in the bottle (due to contact with air and oxygen) and only begin to harden after bonding under anaerobic conditions and metal-to-metal contact. Curing starts at the metal surface and progresses into the bond gap. The product cures quickly on steel and copper; on stainless steel and zinc, the Permabond A905 activator may be beneficial.

Mechanical separation — surface seals are separated by lifting or sliding the components sideways. Slight heating can facilitate separation.

Permabond A136 is approved according to WRAS drinking water regulations . These certifications qualify the product for the specified applications — such as direct contact with drinking water in the case of WRAS and KTW approvals.

Permabond A136 typically reaches handling strength after 15 minutes and functional strength after 1 hour at 23 °C on M10 steel. Final strength is reached after 24 hours. On inactive surfaces (stainless steel, zinc) or at low temperatures, the curing time is extended—Permabond A905 activator accelerates the process.

Permabond A136 is a surface and flange gasket (paste consistency, viscosity 500,000 mPa·s, 0.5 mm gap filling, 10 N·m breakaway torque). Permabond MH196 is a red gasket maker (paste consistency 500,000 mPa·s, 0.5 mm gap filling, 20 N·m breakaway torque) — an anaerobic red surface gasket. Both belong to the anaerobic Permabond A series.

The choice depends on the application: Permabond A136 (surface and flange gasket); Permabond MH196 (red gasketmaker); Permabond A129 (pipe sealant gel); Permabond A1058 (pipe sealant paste). For inactive surfaces (stainless steel, zinc, aluminum), Permabond A905 activator should also be used to accelerate curing.

Your question not covered?

Our technical team provides personal advice on material selection, processing questions, and individual requirements. Fast and competent.

Product Specifications

Product Information
Container 50 ml or 200 ml
Manufacturer Permabond Engineering Adhesives Ltd
Brand Permabond
Country of origin Italy
Performance at Full Cure
Shear strength (steel ISO10123) 12 MPa
Dielectric Strength 11 kV/mm
Thermal conductivity 0.19 W/(m.K)
Torque strength (M10 steel ISO10964) Breakloose 10 Nm
Torque strength (M10 steel ISO10964) Prevailing 8 Nm
Physical Properties
Color red
Chemical group Acrylic one-component
Viscosity (adhesives) High viscosity >5000 mPas
Viscosity 2rpm 75000
Viscosity at 20 rpm 18000
Fluorescence Yes
Curing values
Maximum gap fill (mm) 0.5
Handling strength (M10 steel)@23°C <30 minutes
Functional strength (M10 steel)@23°C 2 hours
Ultimate strength (M10 steel)@23°C 24 hours
Thermal Properties
Coefficient of thermal expansion 90 x 10-6 mm/mm/°C
Storage Temperature (°C) 5-25
Operating temperature (°C) -55 to 200