Skip to content

Technical Sprays

Maintenance, assembly, disconnection.

All technical sprays
Search for application

Construction chemicals

Sealing, bonding, flooring.

All construction chemicals
Search for application

PermabondAnaerobic Adhesives & Threadlockers

PERMABOND F 201 HV

High-strength anaerobic adhesive with hydrogen certification (KIWA KE214) — specifically for H₂ systems, valves, and couplings, compliant with EN751-1 and Gastec QA

Viscosity at 20 rpm
5000
Fluorescence
no
Chemical group
Methacrylate ester
Color
Brown

CHF 0.00 / g
  • Brand
  • Manufacturer
  • Container
  • UFI (Unique Formula Identifier)
  • Chemical group
  • Color
  • Viscosity at 20 rpm
  • Specific Gravity
  • Fluorescence
  • Gap fill up to
  • Thread size up to
  • Hand tight (M10 steel)@23°C
  • Functional strength (M10 steel)@23°C
  • Ultimate strength (M10 steel)@23°C
  • Torque strength (M10 steel ISO10964) Breakloose
  • Shear strength (steel ISO10123)
  • Coefficient of thermal expansion
  • Dielectric Strength
  • Thermal conductivity
  • Storage Temperature (°C)
Your selection PERMABOND F 201 HV 49-280.FL.G200
General terms and conditions of business

Internal reference: 49-280.FL.G200
HS code: 35.069.190.000

PERMABOND F 201 HV sample offer

Technical Data

Typical values, not a specification. The technical data sheet (TDS) is binding.

Product Information

Brand
Permabond
Manufacturer
Permabond Engineering Adhesives Ltd
Container
200 g
UFI (Unique Formula Identifier)
FTK0-S0MU-T00S-HQT2

Performance at Full Cure

Torque strength (M10 steel ISO10964) Breakloose
28 N·m
Shear strength (steel ISO10123)
30 MPa
Dielectric Strength
11 kV/mm
Thermal conductivity
0.19 W/(m.K)

Physical Properties

Chemical group
Methacrylate ester
Color
Brown
Viscosity at 20 rpm
5000
Specific Gravity
1.0
Fluorescence
no

Curing values

Functional strength (M10 steel)@23°C
1 hour
Ultimate strength (M10 steel)@23°C
24 hours

Thermal Properties

Coefficient of thermal expansion
90 x 10-6 mm/mm/°C
Storage Temperature (°C)
5-25

Features

Gap fill up to
0.3mm
Thread size up to
M50
Hand tight (M10 steel)@23°C
15 minutes
Keywords
  • Tin
  • WARS
  • Brass
  • Chrome
  • Zinc
  • Stainless steel
  • Structural Steel

Product Description

Permabond F 201 HV is a high-strength anaerobic adhesive with hydrogen certification (KIWA KE214) — specifically for H₂ systems, valves, and couplings, conforming to EN751-1 and Gastec QA.

Permabond anaerobic curing adhesives — crosslink under exclusion of air between metal surfaces, ideal for thread locking, bushings, shaft-hub connections, and potable water applications. F 201 HV is tailored to specific applications — the key properties and areas of use are listed below.

Hydrogen-certified (KIWA + Gastec)

Permabond F 201 HV is a high-viscosity variant with hydrogen certification (KIWA KE214) and Gastec QA EN751-1 conformity. Specifically for H₂ systems, valves, and couplings — the most demanding application for anaerobic adhesives.

F 201 HV in figures
KIWA KE214
H₂
Gastec QA
EN 751-1
WRAS
Drinking water
High viscosity
cured

What sets F 201 HV apart

Hydrogen certification
KIWA KE214 — approved for H₂ systems.
Gastec QA EN 751-1
Gas connection compliance.
WRAS potable water
Approved for water contact.
High viscosity
Gap filling in large joints.
High strength and hardened
Structural connections under pressure.

What is F 201 HV used for?

Hydrogen Systems
H₂ pipelines, valves, couplings — KIWA-certified.
Gas connections
EN 751-1 + Gastec QA compliance.
Potable water systems
WRAS compliance.
Industrial pressure connections
High-stress pipe connections.
Sanitary installations
Potable water and heating components.
Data Sheets & Safety Data Sheet
TDS and SDS in multiple languages — view or download directly.
To the documents →

Processing

1
Clean substrate
Degrease and dust metallic bonding surfaces with Permabond Cleaner A — contaminants prevent curing.
2
Initiator (for inactive metals)
For stainless steel or other inactive metals: brush on Permabond Initiator 41 or activator.
3
Apply anaerobic adhesive
Apply drops or a thin film to one of the two metal surfaces.
4
Joining components
Assemble components immediately — curing begins in the absence of air between the metal surfaces.
5
Curing
Finger-tight in 10–30 min, full strength in 24 h. For H₂ or potable water applications, wait for full cure.

Recommended accessories


F 201 HV in comparison

Direct comparison with related Permabond products from our range.

F 201 HV
Current Product
F 201 →MM 115 Pure →MM 115 blue →
Chemical BaseAnaerobic (Methacrylate)Anaerobic (Methacrylate)Anaerobic MethacrylateAnaerobic Methacrylate
Viscosityhigh viscositysee TDSthixotropicthixotropic
GradeIndustrial / H₂ / GasIndustrial / Drinking waterNSF/ANSI 61MIL-S-46163A Type II
Colorsee TDSsee TDScolorlessblue
Set Timesee TDSsee TDSsee TDSsee TDS
Full Cure24 h24 h24 h24 h
Main applicationH₂ + Gas + Potable WaterPotable Water + High StrengthDrinking Water ThreadlockingIndustrial Threadlocker

Frequently Asked Questions about F 201 HV

Practical application and design questions — answered by SILITECH.

Permabond F 201 HV: High-strength anaerobic adhesive with hydrogen certification (KIWA KE214) — specifically for H₂ systems, valves, and couplings, compliant with EN751-1 and Gastec QA. Main applications: hydrogen systems, gas connections, drinking water systems.

Anaerobic adhesives crosslink in the absence of air between active metal surfaces. As long as the adhesive has contact with oxygen (open bottle, thin layer in air), it remains liquid. When enclosed between two metal surfaces, crosslinking begins within minutes. Ideal for thread locking, bushings, shaft-hub connections — wherever metal is bonded to metal with a tight gap.

Store in the unopened original container in a dry, cool place — Permabond adhesives typically between +5 and +25 °C, exact values see TDS. Consult the Safety Data Sheet (SDS) before use. Observe the expiry date on the packaging. Store cyanoacrylates cool (ideally refrigerated) for maximum shelf life.

In the comparison table above, you will find related Permabond products with different properties — viscosity, mixing ratio, special certification. If you are unsure about the optimal choice, we will be happy to advise you — contact SILITECH with your specific application (substrate pairing, load, curing condition).