Permabond Engineering Adhesives LtdCyanoacrylate (Superglue)

PERMABOND 820

High temperature resistant and biocompatible — the cytotoxicity-tested superglue for hygienic applications.

Chemical group
Ethyl Cyanoacrylate
Color
colorless
Viscosity (adhesives)
Low viscosity <500 MPas
Viscosity mPa.s
90-110

CHF 0.00 / pc.
  • Manufacturer
  • Brand
  • Container
  • Color
  • Country of origin
  • Chemical group
  • Viscosity (adhesives)
  • Viscosity mPa.s
  • Maximum gap fill (mm)
  • Fixture time on steel (sec.)
  • Hand Strength Rubber (sec.)
  • Hand Strength Phenol (sec.)
  • Steel
  • Operating temperature (°C)
  • Hardness (Shore D)
  • Storage Temperature (°C)
  • Final strength
  • Dielectric strength
  • UFI (Unique Formula Identifier)
Your selection PERMABOND 820 49-820.FL
General terms and conditions of business

Internal reference: 49-820.FL
HS code: 3506.9190000

PERMABOND 820 Sample Offer

Technical Data

Typical values, not a specification. The technical data sheet (TDS) is binding.

Product Information

Manufacturer
Permabond Engineering Adhesives Ltd
Brand
Permabond
Container
20 g, 50 g
Country of origin
Italy
UFI (Unique Formula Identifier)
NS00-G0PG-G00V-M1EH

Performance at Full Cure

Dielectric strength
25 kV/mm

Physical Properties

Color
colorless
Chemical group
Ethyl Cyanoacrylate
Viscosity (adhesives)
Low viscosity <500 MPas
Viscosity mPa.s
90-110

Curing values

Maximum gap fill (mm)
0.15
Fixture time on steel (sec.)
10-15
Hand Strength Rubber (sec.)
10-15
Hand Strength Phenol (sec.)
10-15
Final strength
24 hours

Mechanical properties

Hardness (Shore D)
85

Shear strength ISO 4587 in N/mm²

Steel
19-23

Thermal Properties

Operating temperature (°C)
-55 to +165
Storage Temperature (°C)
2-7
Keywords
  • Ethyl cyanoacrylate
  • Low viscosity
  • ISO 10993 cytotoxicity tested for medical devices
  • PERMABOND
  • Cyanoacrylate adhesive
  • plastic adhesive
  • metal adhesive
  • rubber adhesive
  • Industrial cyanoacrylate adhesive
  • High-Temperature-Resistant Cyanoacrylate Adhesive
  • PERMABOND 820
  • Biocompatible Adhesive

Product Description

Permabond 820 is a high-temperature resistant ethyl cyanoacrylate adhesive with additional cytotoxicity testing — the biocompatible representative of the 800 series for medical and hygienic bonding applications.

With a viscosity of 100 mPa·s, 820 is low-viscosity and fills gaps up to 0.15 mm. Its handling strength on steel, Buna-N, and phenol is 10 to 15 seconds—comparable to the other high-temperature variants in the series.

What distinguishes 820 from 801/802/825 is its successful cytotoxicity testing—a fundamental biological safety test for materials that come into contact with the body. This qualifies 820 for applications with product hygiene requirements. The steel tensile strength of 19–23 N/mm² and the high-temperature formulation remain unchanged.

SPECIAL FEATURE

High-temperature resistant + biocompatible — the rare combination of a high-temperature ethyl cyanoacrylate with passed cytotoxicity testing. Qualified for applications with medical or hygiene-related requirements.

Permabond 820 in figures
100
mPa·s viscosity
19–23
N/mm² Steel
Organic
Cytotoxicity OK
Hot
High-temperature variant

What makes Permabond 820 stand out

Biocompatible
Successful cytotoxicity testing — qualified for medical and hygiene-related bonding applications.
High temperature resistant
Significantly higher strength than standard cyanoacrylates at elevated continuous temperatures.
Low-viscosity standard geometry
100 mPa·s and 0.15 mm gap filling — standard adhesive gap without pre-treatment.
Quick hand strength
10–15 seconds on steel, Buna-N and phenol.
Top-level steel strength
19–23 N/mm² shear strength on blasted steel.
Solvent-free
100% reactive — no mixing, no heat curing.

What is Permabond 820 used for?

Medical and hygiene-related adhesives
Cytotoxicity tested — qualified for applications involving skin contact or hygiene-related requirements.
pharmaceutical and packaging industry
Bonding of components with product hygiene-relevant requirements.
Components near heat sources
High-temperature suitability for devices and machines with increased operating temperatures.
General industrial assembly
Standard adhesives when biocompatible behavior is also required.
Multi-specified bonding
When a cyanoacrylate needs to be both heat and biocompatibility tested.

Processing

1
Clean surfaces
Bonding surfaces must be clean, dry, and free of grease. Degrease with acetone or isopropanol. Lightly sand aluminum, copper, and their alloys to remove the oxide layer.
2
Apply adhesive sparingly
Apply Permabond 820 only drop by drop to an adhesive surface — the thin layer is crucial for rapid curing.
3
Joining components
Assemble quickly and align correctly. Apply sufficient pressure so that the adhesive spreads into a thin film.
4
Fixing until hand-tight
Do not disturb or realign until hand strength is achieved (typically a few seconds to one minute, depending on the substrate). Final strength after 24 hours.
5
Remove adhesive residue
Excess adhesive can be removed with Permabond CA Solvent 2, nitromethane, or acetone.
Data Sheets & Safety Data Sheet
Complete TDS and SDS in DE, EN, FR — view or download directly.
To the documents →

Recommended accessories


Important Notes

Not suitable for / Important notes
For porous or difficult surfaces, Permabond CSA activator is recommended. Permabond POP primer is mandatory before bonding PP, PE, PTFE, or silicone. Passing cytotoxicity testing does not replace full medical device certification—application-specific testing is required before serial use.
Storage
Store refrigerated at 2 to 7 °C. Allow the bottle to warm to room temperature before opening — prevents condensation and protects shelf life.

Which Permabond for which application?

Permabond 820 in direct comparison with related cyanoacrylate products.

Permabond 820
Current Product
Permabond 801 →Permabond 802 →Permabond 825 →
ChemistryEthyl CyanoacrylateEthyl-CAEthyl-CAEthyl-CA
Viscosity100 mPa·s10–15 mPa·s90-110 mPa·s100–150 mPa·s
Max. gap fill.0.15 mm0.05 mm0.15 mm0.15 mm
Finger-tight on steel10–15 s10–15 s10–15 s10–20 s
Shear strength steel19-23 N/mm²19-23 N/mm²19-23 N/mm²15–20 N/mm²
Strength / Recommended forBiocompatible
Organic
Ultra-low, WickingMedium viscosity, high temperaturePremium 180 °C / 1,000 h

Frequently asked questions about Permabond 820

Practical application and design questions — answered by SILITECH.

Permabond 820 is an ethyl cyanoacrylate instant adhesive with a viscosity of 100 mPa·s and a maximum gap filling capacity of 0.15 mm. This high-temperature cyanoacrylate adhesive is biocompatible, low-viscosity, and widely applicable.

Permabond 820 reliably bonds steel (19–23 N/mm²), as well as Buna-N rubber and similar elastomers. For polypropylene (PP), polyethylene (PE), PTFE, and silicone, pretreatment with Permabond Polyolefin Primer (POP) is required.

Permabond 820 has passed cytotoxicity testing approved — qualified for demanding industrial applications.

Permabond 820 reaches handling strength on steel in 10–15 seconds. Other typical curing times: 10–15 seconds (Buna N), 10–15 seconds (Phenol). The final strength of 19–23 N/mm² (steel) is reached after 24 hours. Temperature, humidity, and substrate affect the curing rate.

Permabond 820 offers a viscosity of 100 mPa·s, a gap filling capacity of 0.15 mm, and a shear strength of 19–23 N/mm² on steel. Permabond 801 has a viscosity of 10–15 mPa·s, a gap filling capacity of 0.05 mm, and a shear strength of 19–23 N/mm² on steel (ultra-low wicking). Both utilize an ethyl cyanoacrylate base (or a related cyanoacrylate variant).

Permabond 820 should be stored unopened refrigerated at 2 to 7 °C and is stable until the printed expiration date. Allow the bottle to warm to room temperature before opening—this prevents condensation inside, which would reduce its shelf life. Opened bottles remain functional for several months if stored correctly, although the curing rate may decrease over time. We recommend a test bond to check reactivity before critical production applications.

From the Permabond cyanoacrylate range, select according to viscosity and special properties: Permabond 820 (100 mPa·s, 0.15 mm gap width, biocompatible); Permabond 801 (10–15 mPa·s, 0.05 mm, ultra-low viscosity, wicking); Permabond 802 (90–110 mPa·s, 0.15 mm, medium viscosity, high temperature); Permabond 825 (100–150 mPa·s, 0.15 mm, premium 180 °C / 1,000 h). For polypropylene, polyethylene, PTFE, and silicone, pretreatment with Permabond Polyolefin Primer (POP) is always required.