Skip to content

Technical Sprays

Maintenance, assembly, disconnection.

All technical sprays
Search for application

Construction chemicals

Sealing, bonding, flooring.

All construction chemicals
Search for application

Permabondcyanoacrylate (superglue)

PERMABOND 4C40

High-viscosity medical-device-grade cyanoacrylate for large gap filling — faster set times and improved gap filling capacity vs. conventional cyanoacrylates, also for difficult-to-bond polyacetals

Chemical group
Ethyl Cyanoacrylate
Viscosity at 25°C
1200-2400
Specific Gravity
1.1
Viscosity (adhesives)
High viscosity >5000 mPas

CHF 0.00 / pc.
  • Brand
  • Manufacturer
  • Container
  • Chemical group
  • Viscosity at 25°C
  • Specific Gravity
  • Maximum gap fill (mm)
  • Fixture time on steel (sec.)
  • Hand Strength Rubber (sec.)
  • Hand Strength Phenol (sec.)
  • Curing time at 23°C
  • Steel
  • Impact strength (ASTM D-950)
  • Dielectric Constant
  • Hardness (Shore D)
  • Storage Temperature (°C)
  • Viscosity (adhesives)
Your selection PERMABOND 4C40 49-4C40
General terms and conditions of business

Internal reference: 49-4C40
HS code: 350691900

PERMABOND 4C40 Sample Offer

Technical Data

Typical values, not a specification. The technical data sheet (TDS) is binding.

Product Information

Brand
Permabond
Manufacturer
Permabond Engineering Adhesives Ltd
Container
30 g, 500 g
Curing time at 23°C
24 hours

Performance at Full Cure

Impact strength (ASTM D-950)
3-5 kJ/m²

Physical Properties

Chemical group
Ethyl Cyanoacrylate
Viscosity at 25°C
1200-2400
Specific Gravity
1.1
Viscosity (adhesives)
High viscosity >5000 mPas

Electrical Properties

Dielectric Constant
4,5

Curing values

Maximum gap fill (mm)
0.43
Fixture time on steel (sec.)
5-10
Hand Strength Rubber (sec.)
5-10
Hand Strength Phenol (sec.)
5-10

Mechanical properties

Hardness (Shore D)
85

Shear strength ISO 4587 in N/mm²

Steel
20-22

Thermal Properties

Storage Temperature (°C)
2-7
Keywords
  • High viscosity
  • Medical
  • ISO 10993-5 Cytotoxicity
  • USP CLASS VI
  • PERMABOND
  • Cyanoacrylate adhesive
  • Medical adhesive

Product Description

Permabond 4C40 is a high-viscosity, medical-device-grade cyanoacrylate for large gap filling — faster set times and improved gap filling capacity vs. conventional cyanoacrylates, also for difficult-to-bond polyacetals.

Permabond cyanoacrylate instant adhesives in medical device grade — biocompatible (ISO 10993), solvent-free, cross-link in seconds through surface moisture between the components. 4C40 is tailored to specific applications — the most important properties and areas of use are listed below.

Large gap filling + polyacetal

Permabond 4C40 is a medium-high viscosity, medical-grade variant — faster than conventional cyanoacrylates, with improved gap-filling properties. Excellent on difficult-to-bond polyacetals (POM).

4C40 in numbers
High viscosity
large gap
Medical
Device Grade
Polyacetal
POM-compatible
Instant
Setting

What distinguishes 4C40

High viscosity
Gaps up to ~0.5 mm, vertical application possible.
Polyacetal-compatible (POM)
Highly adhesive polymer with poor adhesion.
Faster than conventional CAs
Shorter curing times.
Large gap filling
Tolerance compensation during assembly.
Multi-Substrate
Metals, ceramics, plastics, elastomers.

What is 4C40 used for?

Medical devices with POM components
Polyacetal assembly with medical compliance.
Large gap bonding
Gaps up to ~0.5 mm can be safely filled.
Vertical Application
High viscosity prevents runoff.
Engineering plastics
Hard-to-bond polymers.
Multi-material assembly
Metals, plastics, and elastomers combined.
Data Sheets & Safety Data Sheet
TDS and SDS in multiple languages — view or download directly.
To the documents →

Processing

1
Clean substrate
Degrease bonding surfaces with Permabond Cleaner A or acetone/isopropanol — a clean surface is critical for medical device bonding.
2
Polyolefin primer (if required)
For PP, PE, PTFE or silicone: brush on Permabond POP Primer, allow to dry briefly — otherwise no CA adhesion is possible.
3
Activator CSA (if needed)
For porous or difficult substrates: spray CSA aerosol, let it evaporate — accelerates CA curing.
4
Apply cyanoacrylate sparingly
Apply a drop or thin bead to one bonding surface — not to both sides, otherwise reaction is too fast.
5
Joining + pressing
Join components immediately and correctly aligned, press with defined pressure — adhesive spreads into a thin film.
6
Curing
Tack-free time in seconds to minutes depending on substrate. Full strength after 24 h. Medical device compliance after full cure.

Recommended accessories


4C40 in comparison

Direct comparison with related Permabond products from our range.

4C40
Current Product
4C30 →4C10 →4UV80HV →
Chemical BaseCyanoacrylate (ethyl ester)Cyanoacrylate (ethyl ester)Cyanoacrylate (ethyl ester)Methacrylate ester
Viscosityhigh viscosityMedium Viscositylow viscosityhigh viscosity, opaque
GradeMedical DeviceMedical DeviceMedical DeviceMedical Device (ISO 10993-5)
Colorcolorlesscolorlesscolorlessopaque
Set Time~60 s~30 s<10 s (typical)UV Cure (sec.)
Full Cure24 h24 h24 hUV-cured
Main applicationLarge gap + POMAuto-dispenser, middle columnHard-to-bond rubbersUV Medical Device

Frequently asked questions about 4C40

Practical application and design questions — answered by SILITECH.

Permabond 4C40: High-viscosity, medical-device-grade cyanoacrylate for large gap filling — faster set times and improved gap filling capacity compared to conventional cyanoacrylates, also suitable for difficult-to-bond polyacetals. Main applications: Medical devices with POM components, large gap bonding, vertical applications.

Medical-Device-Grade cyanoacrylates meet elevated purity standards for medical applications — typically ISO-10993 tests (biocompatibility, cytotoxicity). They have the same instant-curing chemistry as standard CAs (cross-linking via surface moisture), but with controlled purity of ingredients for use in medical devices with patient contact or in pharmaceutical products.

Store in the unopened original container in a dry, cool place — Permabond adhesives typically between +5 and +25 °C, exact values see TDS. Consult the Safety Data Sheet (SDS) before use. Observe the expiry date on the packaging. Store cyanoacrylates cool (ideally refrigerated) for maximum shelf life.

In the comparison table above, you will find related Permabond products with different properties — viscosity, mixing ratio, special certification. If you are unsure about the optimal choice, we will be happy to advise you — contact SILITECH with your specific application (substrate pairing, load, curing condition).